

- #Honeywell vista 20p installation manual pdf rev b serial number
- #Honeywell vista 20p installation manual pdf rev b install
Sanyo CR123A, Varta CR123A, or ADEMCO 466.ģ. Note: Replace battery only with: Panasonic CR123A, Duracell DL123A, Observe correct polarity and insert theīattery provided into the battery holder (see Diagram 2). Remove the transmitters cover (if it is notĪlready off) as described in Mounting Step 1.

Note: If the contact loop is not to be used, noĬonnection is needed across its terminals.īATTERY INSTALLATION/REPLACEMENT 1. The loop response time is a nominal 100mSec. The contact loop must use closed circuit devices. Wiring Connections With the battery still not inserted, connect the contact loop (if used) to the units loop terminals (see diagram). 5799 Magnet (obtain separately) shall be mounted adjacent to the alignment marks on the case and the mounting plates alignment strip (see Diagram 2). If the units reed switch is to be used, a No. The locking tab will click as the case back locks in place.Ħ. Attach the case back to the mounting plate by sliding the keyhole slots in the case back down onto the mounting plates case holding posts.

#Honeywell vista 20p installation manual pdf rev b install
Install the mounting plate, with its case holding posts pointing up (in this example), in the location selected as described in the control units installation instructions. Wiring can be run through this breakout in the case when attaching the case in step 5.Ĥ. For surface wiring entry, a thin breakout area is provided in the case wall. If a wired contact loop is to be used with concealed wiring, feed the wires through the concealed wiring entry hole at one corner of the mounting plate. Disengage the supplied mounting plate from the unit by inserting the blade of a small screwdriver into the locking tab release window (see Diagram 2) and pressing it against the locking tab (see Diagram 1) while sliding the plate downward along the case back.ģ. The flat blade of a small screwdriver into the pry-off slot at the end of the unit farthest from the covers decorative ribs, and twisting the blade.Ģ. Remove the transmitters cover by inserting The unit may, however, be installed in any direction, as long as the relationship of the unit to its mounting plate and (if used) magnet is maintained.Īlthough two holes are provided in the unit that would permit mounting directly to a surface (holes A in Diagram 2) it is recommended that the mounting plate be used, for ease in removing the unit for servicing should it become necessary.īefore mounting the transmitter permanently, conduct Go/No Go tests (see controls instructions) to verify adequate signal strength and reorient or relocate the transmitter if necessary. The description that follows assumes that the unit will be mounted as shown in the diagrams, with the magnet (if used) located to the units right. INSTALLATION Mounting For proper orientation of the unit in relation to the mounting plate, loop wiring, and/or magnet, read all of this section before installing the unit. For UL installations, a contact may not be more than 3 feet from the transmitter.Ī built-in cover tamper switch is activated when the cover is removed. The 5816 has two unique zones the first is for a wired closed circuit contact loop and the second for its built-in reed switch (used in conjunction with a magnet as described below). Note: During programming of the control unit, 5816 transmitters shall be treated as RF (i.e., supervised RF) Type (mandatory for UL installations). Refer to the control units installation instructions for further details.
#Honeywell vista 20p installation manual pdf rev b serial number
You must enroll the transmitter serial number in the control prior to its usage in the system. GENERAL INFORMATION The 5816 Door/Window Transmitter has its own unique serial number permanently assigned during manufacture. Door/Window TransmitterINSTALLATION AND SETUP GUIDEĪLIGN MAGNETWITH MARKS ONCASE AND GUIDEON MTG.
